Specifications

Bay Width: 8 or 9.6 metre bay width
Post Spacing: 4 metres between posts
Height to gutter: 4.3—5.3 metres to height of gutter
Total Height: 6.7—7.7 metres to total height
Ventilation: Double vent 25% of floor area
Ventilation Mechanisms: Ridder motors and controllers, indirect Geared rack and pinion system
Frame Guard tape: fitted to all roof members that touch the plastic
Roof cladding: Single or double-skin Celloclim bubble film or polycarbonate
Wall cladding: Single or double-skin Celloclim bubble film or polycarbonate
Gutters Aluminium with condensation collection
Awning: Top and bottom awning aluminium
Doors: Sliding door with 1150mm metal kick panel at bottom Plastic top panel
Footings: 1 metre deep x 0.450 diameter (depending on soil type) with 150mm x 150mm pedestal for post connection
Wind load: Designed to local municipality wind category requirements
Crop loading: Designed to individual loading requirements

Build time is approximately 8-10 weeks from receipt of deposit to on-site construction